Variability of plantar pressure data

A comparison of the two-step and midgait methods

Thomas G. McPoil, Mark W Cornwall, Lisa Dupuis, Michelle Cornwell

Research output: Contribution to journalArticle

115 Citations (Scopus)

Abstract

The number of trials required to obtain a reliable representation of the plantar pressure pattern is an important factor in the assessment of people with insensate feet or the use of plantar pressure data as a basis for fabrication of foot orthoses. Traditionally, the midgait method has been used for the collection of pressure data, but the large number of walking trials required by this method can increase the risk of injury to the plantar surface of the insensate foot. As a result, the two-step method of plantar pressure data collection has been advocated. The purpose of this investigation was to determine the degree of variability in regional plantar pressure measurements using the midgait and two-step methods of data collection. Plantar pressure data were collected from ten volunteers (five men and five women) between the ages of 20 and 35 years in 20 trials using both data-collection protocols. The results of the study indicate that three to five walking trials are needed to obtain reliable regional peak pressure and pressure-time integral values when the two-step data-collection protocol is used. Although either method can be used for pressure data collection, one method should be used consistently when repeated assessments are required.

Original languageEnglish (US)
Pages (from-to)495-501
Number of pages7
JournalJournal of the American Podiatric Medical Association
Volume89
Issue number10
StatePublished - Oct 1999

Fingerprint

Pressure
Walking
Foot
Foot Orthoses
Volunteers
Wounds and Injuries

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Variability of plantar pressure data : A comparison of the two-step and midgait methods. / McPoil, Thomas G.; Cornwall, Mark W; Dupuis, Lisa; Cornwell, Michelle.

In: Journal of the American Podiatric Medical Association, Vol. 89, No. 10, 10.1999, p. 495-501.

Research output: Contribution to journalArticle

@article{b7b6b30bbccc4736ab0d34956618f354,
title = "Variability of plantar pressure data: A comparison of the two-step and midgait methods",
abstract = "The number of trials required to obtain a reliable representation of the plantar pressure pattern is an important factor in the assessment of people with insensate feet or the use of plantar pressure data as a basis for fabrication of foot orthoses. Traditionally, the midgait method has been used for the collection of pressure data, but the large number of walking trials required by this method can increase the risk of injury to the plantar surface of the insensate foot. As a result, the two-step method of plantar pressure data collection has been advocated. The purpose of this investigation was to determine the degree of variability in regional plantar pressure measurements using the midgait and two-step methods of data collection. Plantar pressure data were collected from ten volunteers (five men and five women) between the ages of 20 and 35 years in 20 trials using both data-collection protocols. The results of the study indicate that three to five walking trials are needed to obtain reliable regional peak pressure and pressure-time integral values when the two-step data-collection protocol is used. Although either method can be used for pressure data collection, one method should be used consistently when repeated assessments are required.",
author = "McPoil, {Thomas G.} and Cornwall, {Mark W} and Lisa Dupuis and Michelle Cornwell",
year = "1999",
month = "10",
language = "English (US)",
volume = "89",
pages = "495--501",
journal = "Journal of the American Podiatric Medical Association",
issn = "8750-7315",
publisher = "American Podiatric Medical Association",
number = "10",

}

TY - JOUR

T1 - Variability of plantar pressure data

T2 - A comparison of the two-step and midgait methods

AU - McPoil, Thomas G.

AU - Cornwall, Mark W

AU - Dupuis, Lisa

AU - Cornwell, Michelle

PY - 1999/10

Y1 - 1999/10

N2 - The number of trials required to obtain a reliable representation of the plantar pressure pattern is an important factor in the assessment of people with insensate feet or the use of plantar pressure data as a basis for fabrication of foot orthoses. Traditionally, the midgait method has been used for the collection of pressure data, but the large number of walking trials required by this method can increase the risk of injury to the plantar surface of the insensate foot. As a result, the two-step method of plantar pressure data collection has been advocated. The purpose of this investigation was to determine the degree of variability in regional plantar pressure measurements using the midgait and two-step methods of data collection. Plantar pressure data were collected from ten volunteers (five men and five women) between the ages of 20 and 35 years in 20 trials using both data-collection protocols. The results of the study indicate that three to five walking trials are needed to obtain reliable regional peak pressure and pressure-time integral values when the two-step data-collection protocol is used. Although either method can be used for pressure data collection, one method should be used consistently when repeated assessments are required.

AB - The number of trials required to obtain a reliable representation of the plantar pressure pattern is an important factor in the assessment of people with insensate feet or the use of plantar pressure data as a basis for fabrication of foot orthoses. Traditionally, the midgait method has been used for the collection of pressure data, but the large number of walking trials required by this method can increase the risk of injury to the plantar surface of the insensate foot. As a result, the two-step method of plantar pressure data collection has been advocated. The purpose of this investigation was to determine the degree of variability in regional plantar pressure measurements using the midgait and two-step methods of data collection. Plantar pressure data were collected from ten volunteers (five men and five women) between the ages of 20 and 35 years in 20 trials using both data-collection protocols. The results of the study indicate that three to five walking trials are needed to obtain reliable regional peak pressure and pressure-time integral values when the two-step data-collection protocol is used. Although either method can be used for pressure data collection, one method should be used consistently when repeated assessments are required.

UR - http://www.scopus.com/inward/record.url?scp=0033212098&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033212098&partnerID=8YFLogxK

M3 - Article

VL - 89

SP - 495

EP - 501

JO - Journal of the American Podiatric Medical Association

JF - Journal of the American Podiatric Medical Association

SN - 8750-7315

IS - 10

ER -