Strength of bearing area confined by fiber-reinforced concrete

Tanner L. Wytroval, Robin G Tuchscherer

Research output: Contribution to journalArticle

Abstract

The research project described in this paper examined the influence of steel fiber-reinforced concrete (SFRC) on the strength of confined bearing areas. Twenty-four 12 x 24 in. (300 x 610 mm) cylindrical specimens were loaded to failure through 6 and 3 in. (150 and 75 mm) diameter bearing plates. Experimental variables included transverse reinforcement ratios ranging between 0.0 and 0.8%, and steel fiber dosages between 0.0 and 1.5% by volume. Specimens were uniaxially loaded to failure while displacement and load data were collected. Increases in bearing strength between 12 and 38% were obtained for specimens with 1% fibers when compared to similar specimens not containing fibers. Upon conclusion of this study, the authors observed that bearing areas surrounded by concrete containing steel fibers were able to attain a higher resistance to bearing loads than specimens without fibers. As a result, bearing areas confined by SFRC, and by steel fibers in combination with stirrups, may potentially be relied on to resist larger compressive loads than areas not reinforced with steel fibers. The findings of this study support an increase of the ACI 318-11 (Section 10.14) bearing strength limitation for areas surrounded by SFRC.

Original languageEnglish (US)
Pages (from-to)1185-1195
Number of pages11
JournalACI Structural Journal
Volume113
Issue number6
DOIs
StatePublished - Nov 1 2016

Fingerprint

Bearings (structural)
Steel fibers
Reinforced concrete
Fibers
Reinforcement
Concretes

Keywords

  • Bearing strength
  • Steel fiber-reinforced concrete
  • Triaxial confinement

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction

Cite this

Strength of bearing area confined by fiber-reinforced concrete. / Wytroval, Tanner L.; Tuchscherer, Robin G.

In: ACI Structural Journal, Vol. 113, No. 6, 01.11.2016, p. 1185-1195.

Research output: Contribution to journalArticle

@article{8e59a4947c65432994af18d31c99d0b6,
title = "Strength of bearing area confined by fiber-reinforced concrete",
abstract = "The research project described in this paper examined the influence of steel fiber-reinforced concrete (SFRC) on the strength of confined bearing areas. Twenty-four 12 x 24 in. (300 x 610 mm) cylindrical specimens were loaded to failure through 6 and 3 in. (150 and 75 mm) diameter bearing plates. Experimental variables included transverse reinforcement ratios ranging between 0.0 and 0.8{\%}, and steel fiber dosages between 0.0 and 1.5{\%} by volume. Specimens were uniaxially loaded to failure while displacement and load data were collected. Increases in bearing strength between 12 and 38{\%} were obtained for specimens with 1{\%} fibers when compared to similar specimens not containing fibers. Upon conclusion of this study, the authors observed that bearing areas surrounded by concrete containing steel fibers were able to attain a higher resistance to bearing loads than specimens without fibers. As a result, bearing areas confined by SFRC, and by steel fibers in combination with stirrups, may potentially be relied on to resist larger compressive loads than areas not reinforced with steel fibers. The findings of this study support an increase of the ACI 318-11 (Section 10.14) bearing strength limitation for areas surrounded by SFRC.",
keywords = "Bearing strength, Steel fiber-reinforced concrete, Triaxial confinement",
author = "Wytroval, {Tanner L.} and Tuchscherer, {Robin G}",
year = "2016",
month = "11",
day = "1",
doi = "10.14359/51689019",
language = "English (US)",
volume = "113",
pages = "1185--1195",
journal = "ACI Structural Journal",
issn = "0889-3241",
publisher = "American Concrete Institute",
number = "6",

}

TY - JOUR

T1 - Strength of bearing area confined by fiber-reinforced concrete

AU - Wytroval, Tanner L.

AU - Tuchscherer, Robin G

PY - 2016/11/1

Y1 - 2016/11/1

N2 - The research project described in this paper examined the influence of steel fiber-reinforced concrete (SFRC) on the strength of confined bearing areas. Twenty-four 12 x 24 in. (300 x 610 mm) cylindrical specimens were loaded to failure through 6 and 3 in. (150 and 75 mm) diameter bearing plates. Experimental variables included transverse reinforcement ratios ranging between 0.0 and 0.8%, and steel fiber dosages between 0.0 and 1.5% by volume. Specimens were uniaxially loaded to failure while displacement and load data were collected. Increases in bearing strength between 12 and 38% were obtained for specimens with 1% fibers when compared to similar specimens not containing fibers. Upon conclusion of this study, the authors observed that bearing areas surrounded by concrete containing steel fibers were able to attain a higher resistance to bearing loads than specimens without fibers. As a result, bearing areas confined by SFRC, and by steel fibers in combination with stirrups, may potentially be relied on to resist larger compressive loads than areas not reinforced with steel fibers. The findings of this study support an increase of the ACI 318-11 (Section 10.14) bearing strength limitation for areas surrounded by SFRC.

AB - The research project described in this paper examined the influence of steel fiber-reinforced concrete (SFRC) on the strength of confined bearing areas. Twenty-four 12 x 24 in. (300 x 610 mm) cylindrical specimens were loaded to failure through 6 and 3 in. (150 and 75 mm) diameter bearing plates. Experimental variables included transverse reinforcement ratios ranging between 0.0 and 0.8%, and steel fiber dosages between 0.0 and 1.5% by volume. Specimens were uniaxially loaded to failure while displacement and load data were collected. Increases in bearing strength between 12 and 38% were obtained for specimens with 1% fibers when compared to similar specimens not containing fibers. Upon conclusion of this study, the authors observed that bearing areas surrounded by concrete containing steel fibers were able to attain a higher resistance to bearing loads than specimens without fibers. As a result, bearing areas confined by SFRC, and by steel fibers in combination with stirrups, may potentially be relied on to resist larger compressive loads than areas not reinforced with steel fibers. The findings of this study support an increase of the ACI 318-11 (Section 10.14) bearing strength limitation for areas surrounded by SFRC.

KW - Bearing strength

KW - Steel fiber-reinforced concrete

KW - Triaxial confinement

UR - http://www.scopus.com/inward/record.url?scp=84996844038&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84996844038&partnerID=8YFLogxK

U2 - 10.14359/51689019

DO - 10.14359/51689019

M3 - Article

AN - SCOPUS:84996844038

VL - 113

SP - 1185

EP - 1195

JO - ACI Structural Journal

JF - ACI Structural Journal

SN - 0889-3241

IS - 6

ER -