Seismic tests on precast segmental concrete columns with unbonded tendons

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

Four unbonded post-tensioned precast segmental concrete columns were subjected to pseudostatic simulated lateral seismic loading in the Charles Lee Powell Structural Research Laboratories at the University of California at San Diego. The influence of parameters including steel jacket confinement, prestress level, and column aspect ratio on column force-deformation characteristics, energy dissipation, damage level, and failure mode was studied. To investigate prestress influence and damage repairability, each column was tested twice: the first test with a given prestress level and a second test, subsequent to column repair, with higher initial prestressing. Shear keys were not provided at segment interfaces, and thus shear was transferred by a friction mechanism. Ductile flexural response was observed in all tests, and maximum column drift levels of 4-6% were achieved. Damage included minor concrete crushing at the interface of column and footing, steel jacket inelastic straining, and residual drift on the order of one-half per cent. Key test results are compared to those predicted by a simple analytical model and good agreement is observed. It is concluded that this structural system can be designed to resist severe seismic demands while offering the benefit of reduced post-earthquake damage and the associated economic loss.

Original languageEnglish (US)
Pages (from-to)215-227
Number of pages13
JournalBridge Structures
Volume3
Issue number3-4
DOIs
StatePublished - 2007

Fingerprint

Precast concrete
Tendons
Prestressing
Steel
Crushing
Research laboratories
Failure modes
Aspect ratio
Analytical models
Energy dissipation
Earthquakes
Repair
Concretes
Friction
Economics

Keywords

  • Bridges
  • Precast concrete
  • Prestressed concrete
  • Segmental concrete
  • Seismic response
  • Unbonded post-tensioning

ASJC Scopus subject areas

  • Building and Construction

Cite this

Seismic tests on precast segmental concrete columns with unbonded tendons. / Hewes, Joshua T.

In: Bridge Structures, Vol. 3, No. 3-4, 2007, p. 215-227.

Research output: Contribution to journalArticle

@article{4ac1a5a3d1f246989755c7ba50039180,
title = "Seismic tests on precast segmental concrete columns with unbonded tendons",
abstract = "Four unbonded post-tensioned precast segmental concrete columns were subjected to pseudostatic simulated lateral seismic loading in the Charles Lee Powell Structural Research Laboratories at the University of California at San Diego. The influence of parameters including steel jacket confinement, prestress level, and column aspect ratio on column force-deformation characteristics, energy dissipation, damage level, and failure mode was studied. To investigate prestress influence and damage repairability, each column was tested twice: the first test with a given prestress level and a second test, subsequent to column repair, with higher initial prestressing. Shear keys were not provided at segment interfaces, and thus shear was transferred by a friction mechanism. Ductile flexural response was observed in all tests, and maximum column drift levels of 4-6{\%} were achieved. Damage included minor concrete crushing at the interface of column and footing, steel jacket inelastic straining, and residual drift on the order of one-half per cent. Key test results are compared to those predicted by a simple analytical model and good agreement is observed. It is concluded that this structural system can be designed to resist severe seismic demands while offering the benefit of reduced post-earthquake damage and the associated economic loss.",
keywords = "Bridges, Precast concrete, Prestressed concrete, Segmental concrete, Seismic response, Unbonded post-tensioning",
author = "Hewes, {Joshua T}",
year = "2007",
doi = "10.1080/15732480701520352",
language = "English (US)",
volume = "3",
pages = "215--227",
journal = "Bridge Structures",
issn = "1573-2487",
publisher = "Taylor and Francis Ltd.",
number = "3-4",

}

TY - JOUR

T1 - Seismic tests on precast segmental concrete columns with unbonded tendons

AU - Hewes, Joshua T

PY - 2007

Y1 - 2007

N2 - Four unbonded post-tensioned precast segmental concrete columns were subjected to pseudostatic simulated lateral seismic loading in the Charles Lee Powell Structural Research Laboratories at the University of California at San Diego. The influence of parameters including steel jacket confinement, prestress level, and column aspect ratio on column force-deformation characteristics, energy dissipation, damage level, and failure mode was studied. To investigate prestress influence and damage repairability, each column was tested twice: the first test with a given prestress level and a second test, subsequent to column repair, with higher initial prestressing. Shear keys were not provided at segment interfaces, and thus shear was transferred by a friction mechanism. Ductile flexural response was observed in all tests, and maximum column drift levels of 4-6% were achieved. Damage included minor concrete crushing at the interface of column and footing, steel jacket inelastic straining, and residual drift on the order of one-half per cent. Key test results are compared to those predicted by a simple analytical model and good agreement is observed. It is concluded that this structural system can be designed to resist severe seismic demands while offering the benefit of reduced post-earthquake damage and the associated economic loss.

AB - Four unbonded post-tensioned precast segmental concrete columns were subjected to pseudostatic simulated lateral seismic loading in the Charles Lee Powell Structural Research Laboratories at the University of California at San Diego. The influence of parameters including steel jacket confinement, prestress level, and column aspect ratio on column force-deformation characteristics, energy dissipation, damage level, and failure mode was studied. To investigate prestress influence and damage repairability, each column was tested twice: the first test with a given prestress level and a second test, subsequent to column repair, with higher initial prestressing. Shear keys were not provided at segment interfaces, and thus shear was transferred by a friction mechanism. Ductile flexural response was observed in all tests, and maximum column drift levels of 4-6% were achieved. Damage included minor concrete crushing at the interface of column and footing, steel jacket inelastic straining, and residual drift on the order of one-half per cent. Key test results are compared to those predicted by a simple analytical model and good agreement is observed. It is concluded that this structural system can be designed to resist severe seismic demands while offering the benefit of reduced post-earthquake damage and the associated economic loss.

KW - Bridges

KW - Precast concrete

KW - Prestressed concrete

KW - Segmental concrete

KW - Seismic response

KW - Unbonded post-tensioning

UR - http://www.scopus.com/inward/record.url?scp=79960181955&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79960181955&partnerID=8YFLogxK

U2 - 10.1080/15732480701520352

DO - 10.1080/15732480701520352

M3 - Article

VL - 3

SP - 215

EP - 227

JO - Bridge Structures

JF - Bridge Structures

SN - 1573-2487

IS - 3-4

ER -