Abstract

A novel gas sensor design has been developed using embedded piezoresistive microcantilever (EPM) technology. In this design, a small piezoresistive microcantilever is embedded or partially embedded into a sensing material that swells slightly upon analyte exposure. This swelling is measured as a simple resistance change in the piezoresistive cantilever, and thus the analyte is detected. Here, we have used an Ni-containing polymer, poly(ethylene oxide), as the active sensing material. This EPM sensor is then used to detect the presence of carbon monoxide gas. For small exposures, the sensor is fully recoverable; however for very large exposures, irreversible chemical changes in the polymeric sensing material occur.

Original languageEnglish (US)
Pages (from-to)474-479
Number of pages6
JournalSensors and Actuators, B: Chemical
Volume99
Issue number2-3
DOIs
StatePublished - May 1 2004

Fingerprint

Gases
sensors
Sensors
gases
Carbon Monoxide
ethylene oxide
Polyethylene oxides
Chemical sensors
Carbon monoxide
swelling
carbon monoxide
Swelling
Polymers
polymers

Keywords

  • Carbon monoxide
  • Embedded
  • Microcantilever
  • Piezoresistive

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry
  • Electrical and Electronic Engineering

Cite this

Gas sensing using embedded piezoresistive microcantilever sensors. / Kooser, Ara; Gunter, Robert L.; Delinger, William G; Porter, Timothy L.; Eastman, Michael P.

In: Sensors and Actuators, B: Chemical, Vol. 99, No. 2-3, 01.05.2004, p. 474-479.

Research output: Contribution to journalArticle

Kooser, Ara ; Gunter, Robert L. ; Delinger, William G ; Porter, Timothy L. ; Eastman, Michael P. / Gas sensing using embedded piezoresistive microcantilever sensors. In: Sensors and Actuators, B: Chemical. 2004 ; Vol. 99, No. 2-3. pp. 474-479.
@article{ffb2d6f1fa274146a67652e434ab02af,
title = "Gas sensing using embedded piezoresistive microcantilever sensors",
abstract = "A novel gas sensor design has been developed using embedded piezoresistive microcantilever (EPM) technology. In this design, a small piezoresistive microcantilever is embedded or partially embedded into a sensing material that swells slightly upon analyte exposure. This swelling is measured as a simple resistance change in the piezoresistive cantilever, and thus the analyte is detected. Here, we have used an Ni-containing polymer, poly(ethylene oxide), as the active sensing material. This EPM sensor is then used to detect the presence of carbon monoxide gas. For small exposures, the sensor is fully recoverable; however for very large exposures, irreversible chemical changes in the polymeric sensing material occur.",
keywords = "Carbon monoxide, Embedded, Microcantilever, Piezoresistive",
author = "Ara Kooser and Gunter, {Robert L.} and Delinger, {William G} and Porter, {Timothy L.} and Eastman, {Michael P.}",
year = "2004",
month = "5",
day = "1",
doi = "10.1016/j.snb.2003.12.057",
language = "English (US)",
volume = "99",
pages = "474--479",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",
number = "2-3",

}

TY - JOUR

T1 - Gas sensing using embedded piezoresistive microcantilever sensors

AU - Kooser, Ara

AU - Gunter, Robert L.

AU - Delinger, William G

AU - Porter, Timothy L.

AU - Eastman, Michael P.

PY - 2004/5/1

Y1 - 2004/5/1

N2 - A novel gas sensor design has been developed using embedded piezoresistive microcantilever (EPM) technology. In this design, a small piezoresistive microcantilever is embedded or partially embedded into a sensing material that swells slightly upon analyte exposure. This swelling is measured as a simple resistance change in the piezoresistive cantilever, and thus the analyte is detected. Here, we have used an Ni-containing polymer, poly(ethylene oxide), as the active sensing material. This EPM sensor is then used to detect the presence of carbon monoxide gas. For small exposures, the sensor is fully recoverable; however for very large exposures, irreversible chemical changes in the polymeric sensing material occur.

AB - A novel gas sensor design has been developed using embedded piezoresistive microcantilever (EPM) technology. In this design, a small piezoresistive microcantilever is embedded or partially embedded into a sensing material that swells slightly upon analyte exposure. This swelling is measured as a simple resistance change in the piezoresistive cantilever, and thus the analyte is detected. Here, we have used an Ni-containing polymer, poly(ethylene oxide), as the active sensing material. This EPM sensor is then used to detect the presence of carbon monoxide gas. For small exposures, the sensor is fully recoverable; however for very large exposures, irreversible chemical changes in the polymeric sensing material occur.

KW - Carbon monoxide

KW - Embedded

KW - Microcantilever

KW - Piezoresistive

UR - http://www.scopus.com/inward/record.url?scp=2342448437&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=2342448437&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2003.12.057

DO - 10.1016/j.snb.2003.12.057

M3 - Article

VL - 99

SP - 474

EP - 479

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

IS - 2-3

ER -