A transcutaneous wire interface for small mammals using an expanded PTFE patch

P. J. Schaeffer, David J Pierotti

Research output: Contribution to journalArticle

Abstract

The objective of this paper is to provide the reader with a method of surgical implantation of a transcutaneous wire interface for chronic instrumentation of small mammals, utilizing a non-bioreactive expanded polytetrafluoroethylene (ePTFE) material (W.L. Gore and Associates, Inc., Flagstaff, AZ). We describe the implant assembly, as well as details of the surgical implantation, which will facilitate successful data acquisition. EMG signal from the implant is of a high quality during both rest and activity of the animal and the signal quality is maintained up to at least 7 weeks post-implantation without any sign of infection or other adverse reaction. This represents an improvement in the viability of long-term physiological signal collection via a surgically implanted back plug.

Original languageEnglish (US)
Pages (from-to)81-85
Number of pages5
JournalJournal of Neuroscience Methods
Volume114
Issue number1
DOIs
StatePublished - Feb 15 2002

Fingerprint

Polytetrafluoroethylene
Mammals
Infection

Keywords

  • Animal implant
  • Back plug
  • Chronic instrumentation
  • Electromyography
  • ePTFE

ASJC Scopus subject areas

  • Neuroscience(all)

Cite this

A transcutaneous wire interface for small mammals using an expanded PTFE patch. / Schaeffer, P. J.; Pierotti, David J.

In: Journal of Neuroscience Methods, Vol. 114, No. 1, 15.02.2002, p. 81-85.

Research output: Contribution to journalArticle

@article{e4857dc732c64e8882724449680ca190,
title = "A transcutaneous wire interface for small mammals using an expanded PTFE patch",
abstract = "The objective of this paper is to provide the reader with a method of surgical implantation of a transcutaneous wire interface for chronic instrumentation of small mammals, utilizing a non-bioreactive expanded polytetrafluoroethylene (ePTFE) material (W.L. Gore and Associates, Inc., Flagstaff, AZ). We describe the implant assembly, as well as details of the surgical implantation, which will facilitate successful data acquisition. EMG signal from the implant is of a high quality during both rest and activity of the animal and the signal quality is maintained up to at least 7 weeks post-implantation without any sign of infection or other adverse reaction. This represents an improvement in the viability of long-term physiological signal collection via a surgically implanted back plug.",
keywords = "Animal implant, Back plug, Chronic instrumentation, Electromyography, ePTFE",
author = "Schaeffer, {P. J.} and Pierotti, {David J}",
year = "2002",
month = "2",
day = "15",
doi = "10.1016/S0165-0270(01)00512-X",
language = "English (US)",
volume = "114",
pages = "81--85",
journal = "Journal of Neuroscience Methods",
issn = "0165-0270",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - A transcutaneous wire interface for small mammals using an expanded PTFE patch

AU - Schaeffer, P. J.

AU - Pierotti, David J

PY - 2002/2/15

Y1 - 2002/2/15

N2 - The objective of this paper is to provide the reader with a method of surgical implantation of a transcutaneous wire interface for chronic instrumentation of small mammals, utilizing a non-bioreactive expanded polytetrafluoroethylene (ePTFE) material (W.L. Gore and Associates, Inc., Flagstaff, AZ). We describe the implant assembly, as well as details of the surgical implantation, which will facilitate successful data acquisition. EMG signal from the implant is of a high quality during both rest and activity of the animal and the signal quality is maintained up to at least 7 weeks post-implantation without any sign of infection or other adverse reaction. This represents an improvement in the viability of long-term physiological signal collection via a surgically implanted back plug.

AB - The objective of this paper is to provide the reader with a method of surgical implantation of a transcutaneous wire interface for chronic instrumentation of small mammals, utilizing a non-bioreactive expanded polytetrafluoroethylene (ePTFE) material (W.L. Gore and Associates, Inc., Flagstaff, AZ). We describe the implant assembly, as well as details of the surgical implantation, which will facilitate successful data acquisition. EMG signal from the implant is of a high quality during both rest and activity of the animal and the signal quality is maintained up to at least 7 weeks post-implantation without any sign of infection or other adverse reaction. This represents an improvement in the viability of long-term physiological signal collection via a surgically implanted back plug.

KW - Animal implant

KW - Back plug

KW - Chronic instrumentation

KW - Electromyography

KW - ePTFE

UR - http://www.scopus.com/inward/record.url?scp=0037084006&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037084006&partnerID=8YFLogxK

U2 - 10.1016/S0165-0270(01)00512-X

DO - 10.1016/S0165-0270(01)00512-X

M3 - Article

VL - 114

SP - 81

EP - 85

JO - Journal of Neuroscience Methods

JF - Journal of Neuroscience Methods

SN - 0165-0270

IS - 1

ER -